Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Category 5 testing needs to be completed, was only able to conduct annual portion of test. 7/21/2023
A17.1-1996 : Elevators 2.17 - Drive machine brake 1001.2(b)(15) x x Car does not have emergency brake cable system. Provide and retest. 7/5/2022
A17.1-1996 : Elevators 2.4 - Machine space 1001.2(b)(4) Top of hoistway stop switch missing cover.
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) Replace or service fire extinguisher in control room.
A17.1-1996 : Elevators 3.2 - Car top light and outlet 1001.2(c)(2) Car top outliet has neutral reversed. Repair as needed.
A17.1-1996 : Elevators 4.5 - Access to Hoistway 1001.2(d)(5) The hoistway door access key switch plate on the bottom landing is broken and shall be repaired to operate as designed. 8/10/2020
A17.1-1996 : Elevators 4.5 - Access to Hoistway 1001.2(d)(5) The hoistway door access key switch plate on the bottom landing is broken and shall be repaired to operate as designed. 8/10/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)12 x The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: Phase II did not initiate when the fireman's emergency service key was turned to the “ON” position. Reinspection is required. 4/27/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)12 x x The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: Phase II did not initiate when the fireman's emergency service key was turned to the “ON” position. The unit is locked out of service until it is repaired and a reinspection has been performed. 5/1/2020
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 1206.2a (Pits and Hoistways) Clean pit.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Provide on-site maintenance control program.