Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No The emergency phone fails to establish two-way communication.
A17.1-2016 : Elevators 3.5 - Normal terminal stopping device 8.6.5.14.3(a) Yes No 8.6.4.19.5 The top normal limit is not functioning. The elevator bypasses the directional limit, and travels onto the final limit.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.2 - Hoistway doors 8.11.2.1.4(b) Yes No 2.11.11.5.4 Reduce the meeting edge of the closed hall doors at the sixth floor to be not more than 0.5 inches 12/7/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.5 - Access to Hoistway 8.6.4.14 Hoistway Access Switches No No Repair bottom floor hoistway access switch that is knocked out 2/14/2024