MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
Door motor wiring on top of car needs to be in metal conduit. Install missing covers on pullboxes on top of elevator.
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)3
|
|
|
Install counterweight guard.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
Provide ABC fire extinguisher in elevator machine room.
|
|
MO Minimum : Elevators
|
(K) - Car Platforms and Car Slings
|
(K)5
|
|
|
Install warning chains on bottom side of elevator platform.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
x
|
|
Eliminate gap between horizontal sliding 2 speed hoistway doors at bottom landing.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.7.2 Periodic Test Record (Test Tags)
|
|
|
Install metal test tag documenting periodic testing
|
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)1
|
x
|
x
|
Gradual wedge clamp safety stopping distance with no load exceeds 74 inches.
|
|
conversion
|
conversion
|
n/a
|
|
|
Door reopening device working intermittently. Need to repair or replace same.
|
7/24/2018
|