MO Minimum : Elevators
|
(I) - Pits
|
(I)4
|
No
|
No
|
Counterweight compresses buffer more than 25% while reaching final terminal switch
|
11/13/2025
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
8.6.4.11
|
Yes
|
No
|
Runby is 1". Hoist ropes shall be shortened for proper runby.
|
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.11 Runby (Re-Inspection)
|
Yes
|
No
|
Suspension ropes need to be shortened. Re-inspection required
|
9/13/2023
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
The phone needs to call someone that will answer 24/7. This phone is programmed to call the front desk, no one answered. Re-inspection required
|
4/3/2024
|