MO Minimum : Elevators
|
(A) - Hoistways
|
(A)3
|
|
|
Each hoistway landing in any elevator hoistway shall be provided with a properly working door or gate
|
4/24/2019
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
needs current certificate posted in machine room
|
4/24/2019
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)10 Car Floors
|
|
|
1.4 cab flooring needs to be permanently attached to sub floor with hole for safety key (tripping hazard)
|
4/24/2019
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
1.5--cab lighting needs to be protected by a grill
|
4/24/2019
|
MO Minimum : Elevators
|
(G)2-Alterations
|
8.7.2.14.2 Car Enclosure
|
|
|
1.6 telephone has no dial tone--telephone needs to be connected to a 24 hour service on a direct line
|
4/24/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
8.6.1.6.5 fire extinguisher hasn't been checked since 2016
|
4/24/2019
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)3
|
|
|
4.2 2nd floor hoistway door needs to be repaired and put back in service ( at present the floor buttons are disconnected and door is bolted shut
|
4/24/2019
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
needs current certificate displayed in the machine room
|
6/21/2019
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)10 Car Floors
|
|
|
cab flooring needs to be permanently attached to sub floor and hole for safety key
|
4/24/2019
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
cab lights needs to be protected by grill
|
4/24/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
8.6.1.6.5 fire extinguisher hasn,t been checked since 2016
|
4/24/2019
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
2.4.2.1--suspension ropes need to be shortened
|
4/3/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
1.6 telephone has no signal--line is disconnected
|
4/3/2019
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)2
|
x
|
|
3.6& 5.4--up final does not work
|
4/3/2019
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)7
|
x
|
x
|
governor tripping to high governor needs to be recaliberated
|
4/3/2019
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)1
|
x
|
|
1.2-Stop at rear of cab needsa to work properly
|
4/3/2019
|