Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)3 Each hoistway landing in any elevator hoistway shall be provided with a properly working door or gate 4/24/2019
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate needs current certificate posted in machine room 4/24/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)10 Car Floors 1.4 cab flooring needs to be permanently attached to sub floor with hole for safety key (tripping hazard) 4/24/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting 1.5--cab lighting needs to be protected by a grill 4/24/2019
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure 1.6 telephone has no dial tone--telephone needs to be connected to a 24 hour service on a direct line 4/24/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements 8.6.1.6.5 fire extinguisher hasn't been checked since 2016 4/24/2019
MO Minimum : Elevators (A) - Hoistways (A)3 4.2 2nd floor hoistway door needs to be repaired and put back in service ( at present the floor buttons are disconnected and door is bolted shut 4/24/2019
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate needs current certificate displayed in the machine room 6/21/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)10 Car Floors cab flooring needs to be permanently attached to sub floor and hole for safety key 4/24/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting cab lights needs to be protected by grill 4/24/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements 8.6.1.6.5 fire extinguisher hasn,t been checked since 2016 4/24/2019
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x 2.4.2.1--suspension ropes need to be shortened 4/3/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x 1.6 telephone has no signal--line is disconnected 4/3/2019
MO Minimum : Elevators (F) - Electrical Switches (F)2 x 3.6& 5.4--up final does not work 4/3/2019
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)7 x x governor tripping to high governor needs to be recaliberated 4/3/2019
MO Minimum : Elevators (F) - Electrical Switches (F)1 x 1.2-Stop at rear of cab needsa to work properly 4/3/2019