MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)3
|
|
|
The top emergency exit shall be secured. The latch is damaged.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
ADA Requirement - Buttons are missing braille identification.
|
|
A17.1-2016 : Elevators
|
1.18 - Restricted opening of car or hoistway doors
|
8.6.4.13.1(l)(Door Restrictor)
|
x
|
|
The car door restrictor shall work at all floors.
|
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.2 On-Site Documentation
|
x
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
7/17/2023
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.2(b)(1)
|
x
|
|
Need procedures for inspections and tests not described in A17.2.
|
7/17/2023
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.2(d)(1)
|
x
|
|
Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site.
|
7/17/2023
|
A17.1-2016 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
8.10.2.2.3(r)
|
x
|
|
There is coax and other cables running the length of the hoistway shall be removed from the hoistway. Only pipes, wiring, and ducts used in connection with the elevator may be installed in the hoistway, remove the cables.
|
7/17/2023
|
A17.1-2016 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
8.6.4.7 Cleaning of Pits
|
|
|
The pit shall be kept clean. Clean the pit.
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
x
|
|
A state ID sticker shall be posted on the elevator controller.
|
7/17/2023
|