Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits The pit equipment and oil lines are excessively rusted. Rust and corrosion shall be removed and equipment shall be painted with a rust proof paint. 7/24/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2.6 Sump Pump Covers A sump pump cover is required in the pit. 9/15/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 9/15/2021
conversion conversion conversion - reinspect x Existing cab emergency telephone doe not work and shall be repaired and tested. 8/21/2018
conversion conversion n/a Hydraulic line, buffers, and pit equipment are excessively rusty. The pit equipment shall have corrosion removed and a rust inhibitor applied. 7/24/2019