Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.11.4.2.1 (Re-Inspection) 8.1.2: Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. Replace missing lower pit bulb and cover. 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 8.1.2: Escalator machine spaces(pits) shall be kept clean and free from excessive debris. 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 2018 & 2020: 8.1.2 : truss, upper & lower ends need clean down. (Violation not corrected as of 8/2020) 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate 11 CSR 40-5.100(2) : Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.11.4.2.1 (Re-Inspection) 8.1.2: Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. Replace missing lower pit bulb and cover. 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 8.1.2: Escalator machine spaces(pits) shall be kept clean and free from excessive debris. 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 2018 & 2020: 8.1.2 : truss, upper & lower ends need clean down. (Violation not corrected as of 8/2020) 12/24/2020
A17.1-2016 : Elevators 8.13 - Handrail systems and safety devices 6.1.3.4 (Hand Rails) (Re-Inspection) /7.3.1(a) Handrails will be free of major cracks and pinchpoints. Replace both Handrails. REINSPECTION REQUIRED 11/21/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.11.4.2.1 (Re-Inspection) 8.1.2: Escalator machine spaces(upper and lower pits) shall be kept clean and free from excessive debris. MULTI-YEAR VIOLATION= REINSPECTION REQUIRED TO ENFORCE. > 11/21/2022
conversion conversion n/a truss, upper & lower ends need clean down 6/24/2019
conversion conversion n/a truss, upper & lower ends need clean down 6/24/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate no current certificate 1/14/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning Perform annual clean down 5/18/2023
A17.1-2016 : Elevators 8.12 - Steps, step chains, and trusses 8.6.8.13 Preform annual clean down 8/9/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6.1 Steps with broken treads shall be repaired or replaced x x Replace or repair damaged steps 8/9/2024
A17.1-2016 : Elevators 10.12 - Pallets, pallet chains, and trusses 8.6.8.15.12 x x Replace step chain, stretch beyond acceptable clearances 8/9/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) x 2019-2020: Step demarcation lights not working upper and lower. (2nd year violation) 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6 x Replace step with broken step treads , only one step 5/15/2023