Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a truss , upper & lower end need clean down 6/24/2019
conversion conversion n/a Upper and lower lights & guasrds in truss need replaced 6/24/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) x 2019-2020: Step demarcation lights not working upper and lower (2nd year violation) 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 6.1.7 Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 Escalator machine spaces(pits) shall be kept clean and free from excessive debris. 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 2018&2020: Truss , upper & lower end need clean down (violation not corrected as of 8/2020) 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5.6 :Replace broken step demarcation sections. Reinspection within 30 days 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6 x Slotting in step treads will be parallel with direction of travel. Repair or replace step with bent tread section. (REINSPECTION WITHIN 30 DAYS) 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6 x Slotting in step treads will be parallel with direction of travel. Repair or replace step with bent tread section. (REINSPECTION WITHIN 30 DAYS) 9/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate needs current certificate posted 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6 x Replace broken step Demarcation sections 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 6.1.7 Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 Escalator machine spaces(pits) shall be kept clean and free from excessive debris. 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 2018&2020: Truss , upper & lower end need clean down (violation not corrected as of 8/2020) 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5.6 :Replace broken step demarcation sections. Reinspection within 30 days 1/14/2022
A17.1-2016 : Elevators 7.9 - Steps and upthrust device 8.6.8.6 Slotting in step treads will be parallel with direction of travel. Repair or replace step with bent tread section. (REINSPECTION WITHIN 30 DAYS) 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 6.1.3.4 (Hand rails) (Re-Inspection) x /7.3.1(a) Handrails will be free of major cracks and pinchpoints. Replace both Handrails. REINSPECTION REQUIRED 11/21/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5.6 x Replace loose/damaged/broken step demarcation sections. REINSPECTION REQUIRED 11/21/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.11.4.2.1 (Re-Inspection) x 8.1.2: Escalator machine spaces(upper and lower pits) shall be kept clean and free from excessive debris. MULTI-YEAR VIOLATION= 11/21/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning Perform annual clean down 12/1/2023
A17.1-2016 : Elevators 8.12 - Steps, step chains, and trusses 8.6.8.13 Preform annual clean down 8/9/2024