Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 6.1.7 No No Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 No No Escalator machine spaces(pits) shall be kept clean and free from excessive debris. 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 No No 2018&2020: Truss , upper & lower end need clean down (violation not corrected as of 8/2020) 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5.6 No No :Replace broken step demarcation sections. Reinspection within 30 days 1/14/2022
A17.1-2016 : Elevators 7.9 - Steps and upthrust device 8.6.8.6 No No Slotting in step treads will be parallel with direction of travel. Repair or replace step with bent tread section. (REINSPECTION WITHIN 30 DAYS) 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 6.1.7 No No Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 No No Escalator machine spaces(pits) shall be kept clean and free from excessive debris. 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 No No 2018&2020: Truss , upper & lower end need clean down (violation not corrected as of 8/2020) 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5.6 No No :Replace broken step demarcation sections. Reinspection within 30 days 12/24/2020
conversion conversion n/a No No truss , upper & lower end need clean down 6/24/2019
conversion conversion n/a No No Upper and lower lights & guasrds in truss need replaced 6/24/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate No No needs current certificate posted 1/14/2022
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning No No Perform annual clean down 12/1/2023
A17.1-2016 : Elevators 8.12 - Steps, step chains, and trusses 8.6.8.13 No No Preform annual clean down 8/9/2024
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails No No replace damaged hand rails 9/11/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.6.2(i) Step Demarcation No No provide operational demarcation lights 9/11/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) Yes No 2019-2020: Step demarcation lights not working upper and lower (2nd year violation) 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6 Yes No Slotting in step treads will be parallel with direction of travel. Repair or replace step with bent tread section. (REINSPECTION WITHIN 30 DAYS) 12/24/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6 Yes No Replace broken step Demarcation sections 1/14/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6 Yes No Slotting in step treads will be parallel with direction of travel. Repair or replace step with bent tread section. (REINSPECTION WITHIN 30 DAYS) 9/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 6.1.3.4 (Hand rails) (Re-Inspection) Yes No /7.3.1(a) Handrails will be free of major cracks and pinchpoints. Replace both Handrails. REINSPECTION REQUIRED 11/21/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5.6 Yes No Replace loose/damaged/broken step demarcation sections. REINSPECTION REQUIRED 11/21/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.11.4.2.1 (Re-Inspection) Yes No 8.1.2: Escalator machine spaces(upper and lower pits) shall be kept clean and free from excessive debris. MULTI-YEAR VIOLATION= 11/21/2022