Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Upper and lower demarcation lights not working 3/2/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records No No Need maintenance control program on site
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2 No No Emergency stop switch cover broken off at bottom
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2 No No Wiring going into bottom of controller, greenfield coming apart, needs to be repaired
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.4 Escalator Combplates Yes No complete annual test Bottom comb impact vertical test
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.4 Escalator Combplates No No Replace section comb plate missing teeth
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No Post current state certificate in machine room
conversion conversion n/a No No Handrail torn on left side needs replacing
conversion conversion n/a No No Top E-stop switch, no buzzer on cover Bottom also
conversion conversion n/a No No Handrail inlet cover piece missing
A17.1-1996 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 806 No No Replace greenfield feeding the controller open & pulled loosed
A17.1-1996 : Escalators 7.5 - Lighting 805.7 No No Upper demarcation lights not working
A17.1-1996 : Escalators 8.3 - Controller and wiring 806 No No Electric greenfield in bottom controller, torn open, needs repair
A17.1-1996 : Escalators 7.5 - Lighting 806.2 No No Reinspection of demarcation lightening-failed and torn elect conduit on pit failed. No violations have been corrected. Reinspection needed
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 No No Upper & Lower demarcation lights not working
A17.1-1996 : Elevators 5.7 - Car frame and platform 203.6 No No Electrical greenfield in bottom of controller torn open needs repair