Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits Standing water in pit at time of Inspection 8/6/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room 10/31/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2.5 Sump pump shall be provided GFCI pit receptacle required excluding sump-pump receptacle. A single receptacle shall be used for the sump pump. GFCI shall not be used for the sump pump. When the GFCI disconnects power you don't want the sump pump to stop working. The GFCI must remain in pit a single receptacle shall be added. 15 inches of water in pit.