A17.1-2016 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
the state certificate posted in the machine room is to be updated every year
|
10/13/2022
|
|
A17.1-2016 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
the copy of the state operating certificate on display in the machine room is from 2017, a new copy is to be put in the machine room every year.
|
10/13/2022
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.5 - Car lighting and receptacles
|
8.11.2.1.1(e) Car Lighting
|
|
|
replace the battery for the emergency light and bell, it is dead and will not operate the lights or bell when the 110 volt power is off
|
2/1/2022
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
perform monthly fire service test and post a log in the machine room
|
10/13/2022
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.11 - Disconnecting Means and Control
|
2.26.4
|
|
|
Mark the main line disconnect for the elevator and the 110 disconnect for the cab lights in the machine room with the feeder locations room number, breaker number and panel number
|
|
|
A17.1-2016 : Elevators
|
2.7 - Fire Extinguisher
|
8.11.3.1.2(j)
|
|
|
machine room fire extinguisher inspection tag is from 2019, the extinguisher is to be inspected annually.
|
10/13/2022
|
|
A17.1-2016 : Elevators
|
2.7 - Fire Extinguisher
|
8.11.3.1.2(j)
|
|
|
machine room fire extinguisher inspection tag is from 2019, inspection is to be done annually
|
10/13/2022
|
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.6.11.1 Firefighters’ Emergency Operation Documentation
|
|
|
a copy of the monthly fire service test log is to be posted in the machine room
|
10/13/2022
|