Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 3.23 - Suspension Means 8.6.3.2 (Re-Inspection) Yes No Coated steel suspension belt monitoring device (pulse unit) is showing a trouble code stating "schedule belt replacement". Replace coated belts. Re-inspection required
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) No No Unique procedures or methods for tests and inspections not described in A17.2 shall be kept in the elevator machine room.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No Machine room shall contain on site maintenance records. 6/1/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) No No Unique procedures or methods for tests and inspections not described in A17.2 shall be kept in the elevator machine room. 6/1/2026