Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting x Replace the emergency light battery as yours is dead. 11/17/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5.1 Examination and Maintenance of Packing Glands and Seals x Re-pack the left side packing due to excessive leaking. 11/17/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.33 - Tanks 8.6.5.5 Re-pack the left side jack due to excessive leakage, (this was on last years inspection>) 7/11/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Replace the missing 25 gallons of hydraulic oil from the tank. When the elevator is at the top floor 1/2 of the motor is exposed. 7/11/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Repair the emergency phone as it will dial the number but won't ring out. 6/6/2024