Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 11.11 - Emergency Brake 8.6.4.6.3 x Unintended movement is over 48" (approx 60"), needs repaired. Re-inspection required 12/12/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.8 Switch Keys (Re-Inspection) x All fire service keys for the elevators in one building shall be keyed alike 12/7/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.3 - Firefighters' service (A17.1-1984 through A17.1a-1988 and A17.3) 8.11.2.2.6 x All fire service keys for elevators in one building shall be keyed alike. Re-inspection required 1/21/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x x Unintended car movement test (no load) failed. Car moved approx 7 feet. Red-tagged and removed from service. Re-inspection required 1/21/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Need to perform the following tests to complete Cat 5 full load test: test driving machine brake with 125% of rated load, perform unintended movement test with 125% of rated load, test car safeties with rated load at rated speed, test car buffer with rated load at rated speed & test counterweight buffer at rated speed. Re-inspection required