Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.36 - Hydraulic Cylinders 1004.2(b)(19) 8.6.5.8 Determine if jack is single bottom type and provide documentation of findings on site. 4/1/2021
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate. 4/1/2021
A17.1-1996 : Elevators 2.36 - Hydraulic Cylinders 1004.2(b)(19) Possible single bottom cylinder. If unit is double bottom type provide documentation that can be kept on site. If unit is single bottom, take corrective action. 4/1/2021
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display a copy of the current state operating certificate. 4/1/2021
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.8 Switch Keys Keys were not available to test Fire Service. Keys shall be kept on site at all times. 4/1/2021
A17.1-1996 : Elevators 2.36 - Hydraulic Cylinders 1004.2(b)(19) Possible single bottom cylinder. If unit is double bottom type provide documentation that can be kept on site. If unit is single bottom, take corrective action. 4/1/2021
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 The pit needs to be cleaned.
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.2c (Clean Car Tops) The car top shall be cleaned.
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.2b (Clean Machine Room) Machine room shall be kept clean and free of debris.
MO Minimum : Elevators (H) - Machine Rooms (H)8 Cab light disconnect switch in controller is broken.
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.2-211.8 x x Fire service shall be tested. 2/16/2021
conversion conversion conversion - reinspect x In car phone does not work and shall be repaired and tested. 12/4/2018
conversion conversion conversion - reinspect x Provide documentation that unit does not have a single bottom cylinder. 12/4/2018
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 2/16/2021