Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 Cylinder needs to be repacked.
MO Minimum : Elevators (I) - Pits (I)1 Pit shall be clean and dry.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)7 Door force too high, should be less than 30 pds.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Use of oil recovery system by automatic means prevents proper monitoring of packing glands and seals.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing / worn cab steadier's
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) Need to provide up-to-date wiring diagrams as part of the MCP
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current State Elevator Certificate.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate x Post current State Elevator Certificate.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Car top door operator is missing cover, provide.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Provide existing machine room light to work.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Clean the car top.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Machine room ceiling has water damage, repair or replace as needed.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces Abate black mold on machine room ceiling.
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 OSV is sealed, no tag. Provide testing. Record results.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Alarm bell is not working. 10/16/2019
MO Minimum : Elevators (S) - Fire Service (S)1 x Fire service call cancel not working. When call cancel button is pushed, car stops in between floors. 10/16/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Phone and alarm bell shall work. Ten working days to correct or elevator shall be red-tagged. 11/23/2020
MO Minimum : Elevators (S) - Fire Service (S)1 x x Fireman's Phase II call cancel, when pushed to cancel call elevator stops, then levels into the next floor. 11/23/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency alarm not working. 9/17/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Phone in elevator cab does not work 9/17/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Alarm bell in elevator cab does not work 9/17/2021
MO Minimum : Elevators (S) - Fire Service (S)1 x x Car stopped in the middle of run when car cancel was pushed. Only elevator in building. Red tagged. Repair ASAP. 9/27/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Alarm bell in elevator cab not working 8/4/2022