Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No A17.1 2016 8.6.4.16 The elevator car when landing at the 2nd floor is approximately 1/2” high and shall be adjusted to level in appropriately. 11/21/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 2.16.8 Yes No Emergency power operation and emergency power jewel operations could not be tested due to failiure of genteration operation.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 2.27.2 Yes No Emergency power shall be tested. 11/21/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 2.27.2 Yes No Emergency power needs to be tested. 4/6/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 2.27.2.3 (Elevator Emergency Power Illuminated Signal) No No The emergency power indicating jewel failed to operate when activated, repair light jewel to activate as required. 11/21/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 2.27.2.3 (Elevator Emergency Power Illuminated Signal) Yes No The emergency power jewel must be check when emergency power is tested. 4/6/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Two-way emergency communication device is not functioning and needs repaired. 4/6/2026
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Break test, setting of car safties, unintended movement, asending overspeed and emergecny power testing must be completed to satify full cat 5 test. This could not be completed due to repair needed for the governor reset solenoid. 4/6/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.13 - Governor,overspeed switch and seal 2.17.15 Yes No Governor reset solenoid is not fuctioning and must be repaired/replaced 4/6/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No Provide written maintenance control program on site for each elevator. 11/21/2025