Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.10.4.1.1(e) Upper and lower demarcation lighting inoperative. Repair
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.15 Clean upper pit.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.19 - Maintenance records 8.6.1.4 Provide written record of maintenance to be kept on site.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) x Repair both demarcation lights. 7/18/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.8 - Deck barricades and antislide devices 8.11.4.1(h) Repair outer decking on left side that is loose and not lining up with other decking.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.6.8.1 Both handrails have cracks, replace same
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.6.8.1 Both handrails have cracks. Replace same.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(F) Outer decking on left side is loose, not lining up with other decking, repair same
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records A copy of the MCP shall be kept in the machine room for each unit