Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.11.4.2.13 Replace handrail on right side that has cracks.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 Pit needs cleaning
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A copy of the MCP for each elevator shall be kept in the machine room for each unit
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 Pits need cleaning.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.19 - Maintenance records 8.6.1.4 Provide written records of maintenance to be kept on site.
A17.1-2016 : Elevators 7.5 - Lighting 8.6.11.6.2(i) The demarcation light fixture at the bottom failed to illuminate and shall be repaired/replaced.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) x Demarcation lights on both ends not working. 3/24/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 6.1.6.7 Upper and lower demarcation lights do not work. 4/6/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting x Demarcation lights on both ends are not working, needs repair. Re-inspection required 4/6/2023