Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.33 - Tanks 8.6.5.1 No No A17.1 - 8.6.5.6 Flexible Hoses and Fittings.Flexible Hydraulic Hose over 6 years old. (Replace hose or solid pipe) 9/4/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - n/a n/a No No A17.1 - 8.6.4.7.4 Water and oil shall not be allowed to accumulate on pit floors.(Item 5.1) Oil in pit. (Clean Pit, Replace Jack packing.) 9/4/2026
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(1) No No A17.1 – 2016 8.6.1.4.1 On-Site Maintenance Records 8.6.1.4.1(c)(1) A record of oil usage (8.6.5.7). PROVIDE OIL USAGE LOG. (TO BE PROVIDED BY SERVICE/MAINTENANCE COMPANY). 9/4/2026
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(3) No No A17.1 – 2016 8.6.1.4.1(c)(3) Periodic tests (see 8.6.1.7) shall be documented or recorded in accordance with 8.6.1.7.2. PROVIDE TEST LOG. (TO BE PROVIDED BY SERVICE/MAINTENANCE COMPANY). 9/4/2026
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.2 Callbacks (Trouble Calls) Documentation No No A17.1 – 2016 8.6.1.4.2 Callbacks (Trouble Calls). A record of callbacks shall be maintained and shall include the description of reported trouble, dates, time, and corrective action(s) taken that are reported by any means to elevator personnel. PROVIDE CALLBACK LOG. (TO BE PROVIDED BY SERRVICE/MAINTENANCE COMPANY). 9/4/2026
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(1) No No 8.6.1.4.1(c)(1) A record of oil usage (8.6.5.7). PROVIDE OIL USAGE LOG 9/4/2026
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(3) No No 8.6.1.4.1(c)(3) Periodic tests (see 8.6.1.7) shall be documented or recorded in accordance with 8.6.1.7.2. PROVIDE TEST LOG. 9/4/2026
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.2 Callbacks (Trouble Calls) Documentation No No 8.6.1.4.2 Callbacks (Trouble Calls). A record of callbacks shall be maintained and shall include the description of reported trouble, dates, time, and corrective action(s) taken that are reported by any means to elevator personnel. PROVIDE CALLBACK LOG. 9/4/2026
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation No No 8.6.1.6 General Maintenance Methods and Procedures PROVIDE COPY OF TEST METHODS & PROCEDURES. 9/4/2026