ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 2.27.2.3 (Elevator Emergency Power Illuminated Signal) Emergency power indicator light needs to work when on back-up power.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 2.27.2 x Emergency power indicator light needs to work when on backup power. Re-inspection required 1/6/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.17 - Standby power operation 2.27.2 x Emergency power indicator light needs to work when on backup power. Re-inspection required 1/21/2026
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Need to perform the following tests to complete Cat 5 inspection after governor and rope are replaced: unintended movement, 125% brake, full speed counterweight buffer, full speed, full load car buffer & full speed, full load car safeties. Re-inspection required 1/21/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts x x Overspeed governor failed pull thru test. Red-Tagged and removed from service, need to acquire alteration permit and perform alteration inspection when replaced. 1/21/2026