MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current state operating certificate inside machine
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
Install fire extinguisher inside machine room
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
|
|
Insufficient machine room lighting. Need to install light fixtures to provide 10 ft candles at floor level of entire machine room
|
|
MO Minimum : Elevators
|
(C) - Car Enclosure: Freight
|
(C)6
|
|
|
Post "NO PASSENGERS " sign inside the elevator
|
|
MO Minimum : Elevators
|
(C) - Car Enclosure: Freight
|
(C)2
|
|
x
|
Collapsible gate does not reject 4 1/2 in ball.
|
|
MO Minimum : Elevators
|
(C) - Car Enclosure: Freight
|
(C)2
|
|
x
|
No guides or track for collapsible car gate
|
|
MO Minimum : Elevators
|
(C) - Car Enclosure: Freight
|
(C)2
|
|
x
|
Collapsible gate swings inward before gate is fully open.
|
|
MO Minimum : Elevators
|
(C) - Car Enclosure: Freight
|
(C)2
|
|
x
|
No hand guard on collapsible gate
|
|
MO Minimum : Elevators
|
(C) - Car Enclosure: Freight
|
(C)2
|
|
x
|
Car gate switch is defeatable inside the elevator
|
|