Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state operating certificate inside machine
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Install fire extinguisher inside machine room
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Insufficient machine room lighting. Need to install light fixtures to provide 10 ft candles at floor level of entire machine room
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)6 Post "NO PASSENGERS " sign inside the elevator
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 x Collapsible gate does not reject 4 1/2 in ball.
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 x No guides or track for collapsible car gate
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 x Collapsible gate swings inward before gate is fully open.
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 x No hand guard on collapsible gate
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 x Car gate switch is defeatable inside the elevator