Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current state operating certificate inside machine
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Install fire extinguisher inside machine room
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Insufficient machine room lighting. Need to install light fixtures to provide 10 ft candles at floor level of entire machine room
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)6 No No Post "NO PASSENGERS " sign inside the elevator
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 No Yes Collapsible gate does not reject 4 1/2 in ball.
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 No Yes No guides or track for collapsible car gate
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 No Yes Collapsible gate swings inward before gate is fully open.
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 No Yes No hand guard on collapsible gate
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)2 No Yes Car gate switch is defeatable inside the elevator