Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.16 - Rated load, platform area, and data plate 2.16.3 x no metal data tags 1/19/2022
A17.1-2016 : Elevators 1.18 - Restricted opening of car or hoistway doors 8.11.3.1.1(r) x Provide door restrictor on car doors. 1/18/2023
A17.1-2016 : Elevators 2.14 - Code data plate 8.11.2.1.2(hh) Provide code data plate in machine room.
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 8.11.2.1.2(k) Smoke detector in machine room has paint cover on it.
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone not working. Line? 4/1/2024
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x Shunt trip not overriding emergency battery lowering. Need relay added 4/1/2024
A17.1-2016 : Elevators 2.1 - Access to machine space 2.7.3.4 Machine room door must be self-closing and self-locking
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.4.19.6 x Top hoistway smoke sensor recalls elevator to wrong floor. Need relay added 4/1/2024
A17.1-2016 : Elevators 3.17 - Door and gate equipment 8.6.4.13 Car door needs new leading edge stainless steel wrap around skin.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone not working on DC power, alarm bell ok.
MO Minimum : Elevators (I) - Pits (I)7 Pit stop switch hidden, relocate for clear identification.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light switch is red in color, change to black or white to avoid confusion.
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove all non elevator related items from machine room.
MO Minimum : Elevators (H) - Machine Rooms (H)8 Provide covers for FFS modules in machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone not working, alarm bell ok. 9/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Provide door restrictors on both car doors. 9/27/2023
MO Minimum : Elevators (I) - Pits (I)7 Pit switch not accessible from landing, move closer to the door.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light switch is red in color. Change to black or white to avoid further confusion and safety.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting x car lts not guarded 1/19/2022
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove all non elevator related items from machine room.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Overhead lighting in car is unguarded.
MO Minimum : Elevators (K) - Car Platforms and Car Slings (K)6 Guide roller under car badly cracked and deteriorating.
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure x Emergency lights not working. 1/19/2021
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure x Emergency alarm not working. 1/19/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Fan guard on ceiling not secured well enough, and hanging down.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems x Door reopening devices not working. 8/20/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems x Sheet metal skins on car doors coming loose, repair. 8/20/2021