Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 3.17 - Door and gate equipment 8.6.4.13 No No Car door needs new leading edge stainless steel wrap around skin. 3/26/2026
A17.1-2016 : Elevators 2.1 - Access to machine space 2.7.3.4 No No Machine room door must be self-closing and self-locking 3/26/2026
A17.1-2016 : Elevators 2.14 - Code data plate 8.11.2.1.2(hh) No No Provide code data plate in machine room. 3/26/2026
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 8.11.2.1.2(k) No No Smoke detector in machine room has paint cover on it. 3/26/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Fan guard on ceiling not secured well enough, and hanging down. 3/26/2026
MO Minimum : Elevators (K) - Car Platforms and Car Slings (K)6 No No Guide roller under car badly cracked and deteriorating. 3/26/2026
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No Overhead lighting in car is unguarded. 3/26/2026
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Pit light switch is red in color, change to black or white to avoid confusion. 3/26/2026
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Pit light switch is red in color. Change to black or white to avoid further confusion and safety. 3/26/2026
MO Minimum : Elevators (I) - Pits (I)7 No No Pit stop switch hidden, relocate for clear identification. 3/26/2026
MO Minimum : Elevators (I) - Pits (I)7 No No Pit switch not accessible from landing, move closer to the door. 3/26/2026
MO Minimum : Elevators (H) - Machine Rooms (H)8 No No Provide covers for FFS modules in machine room. 3/26/2026
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Remove all non elevator related items from machine room. 3/26/2026
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Remove all non elevator related items from machine room. 3/26/2026
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working. Line? 4/1/2024
A17.1-2016 : Elevators 1.16 - Rated load, platform area, and data plate 2.16.3 Yes No no metal data tags 1/19/2022
A17.1-2016 : Elevators 1.18 - Restricted opening of car or hoistway doors 8.11.3.1.1(r) Yes No Provide door restrictor on car doors. 1/18/2023
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) Yes No Shunt trip not overriding emergency battery lowering. Need relay added 4/1/2024
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.4.19.6 Yes No Top hoistway smoke sensor recalls elevator to wrong floor. Need relay added 4/1/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Yes No car lts not guarded 1/19/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Yes No Door reopening devices not working. 8/20/2021
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure Yes No Emergency alarm not working. 1/19/2021
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure Yes No Emergency lights not working. 1/19/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency lights not working.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working on DC power, alarm bell ok. 2/18/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working, alarm bell ok. 3/26/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working, alarm bell ok.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not working, alarm bell ok. 9/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No Provide door restrictors on both car doors. 9/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Yes No Sheet metal skins on car doors coming loose, repair. 8/20/2021