conversion
|
conversion
|
conversion - reinspect
|
x
|
|
replace lift manufacures data tag or as a minimum install code tag on main line switch mounted by lift, lift to comply with ASMe a 18.1-2005 edition
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Post a capacity plate in a conspicuous place on lift
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Post the certificate of operation by lift. possibly indoors visible through a window.
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Platform obstruction plate bent dragging on deck landing, provide necessary clearance .375 ins) and straighten plate, test assembly after repairs
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Install restriction signs in a conspicious place at each landing,
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
unsure of lifts suspension, means safety test with a qualified contractor may be nessary
|
|