A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Emergency battery lowering inoperable. Bad battery
|
2/20/2024
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Emergency battery lowering not working. Battery
|
4/1/2024
|
MO Minimum : Elevators
|
(G)2-Alterations
|
8.7.2.14.2 Car Enclosure
|
x
|
|
Emergency lights weak.
|
1/19/2021
|
A17.1-2016 : Elevators
|
2.8 - Pipes, wiring, and ducts
|
8.11.2.1.2(k)
|
|
|
FFS modules in machine room missing covers.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
x
|
|
Machroom door lock defeatable
|
1/19/2022
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
New smoke detectors present in machine room, but not connected to controller.
|
9/26/2023
|
A17.1-2016 : Elevators
|
1.16 - Rated load, platform area, and data plate
|
2.16.3
|
x
|
|
no metal data tags
|
1/19/2022
|
A17.1-2016 : Elevators
|
2.14 - Code data plate
|
8.11.2.1.2(hh)
|
|
|
Provide code data plate in machine room.
|
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
Provide covers for FFS modules in machine room.
|
9/26/2023
|
A17.1-2016 : Elevators
|
1.18 - Restricted opening of car or hoistway doors
|
8.11.2.1.1(r)
|
x
|
|
Provide door restrictors for each car door.
|
1/19/2023
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Shunt trip battery override needs testing with good battery
|
2/20/2024
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Shunt trip not overriding battery lowering. Need relay added
|
4/1/2024
|
A17.1-2016 : Elevators
|
2.8 - Pipes, wiring, and ducts
|
2.8.2
|
x
|
|
Shunt trip not overriding emergency battery lowering
|
10/28/2024
|
A17.1-2016 : Elevators
|
2.8 - Pipes, wiring, and ducts
|
8.11.2.1.2(k)
|
|
|
Smoke and heat detector wiring exposed, not in conduit.
|
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.6.4.19.6
|
x
|
|
Top of hoistway smoke recalls to wrong floor
|
4/1/2024
|