ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.7 - Car door or gate
|
2.14.4
|
x
|
|
Repair bent pick up roller assembly on landing one hoistway door (2.14.4.2.4)
|
8/30/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.6 - Ventilation
|
2.7.5.2
|
|
|
Repair AC unit and maintain manufacturer's recommended operating range
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.6 - Ventilation
|
2.7.5.2
|
|
|
machine room air conditioner is not working, repair air conditioner so machine room is maintained at the manufacturer's recommended temperature range and humidity
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.6 - Ventilation
|
2.7.5.2
|
|
|
Machine room air conditioner is not working, repair air conditioner so room is maintained at the manufacturer's recommended temperature range
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
The building shall post the operating certificate in the elevator equipment room, and it needs to be updated with a new copy annually. the certificate on display in the machine room is from 2019
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
post current copy of state operating certificate in the machine room
|
|
A17.1-2016 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
the copy of the state operating certificate posted in the machine room is to be updated annually
|
|
A17.1-2016 : Elevators
|
2.6 - Ventilation
|
8.11.2.1.2(i)
|
|
|
the controller room air conditioner does not appear to be working, repair the air conditioner so the room is maintained at the recommended temperature per the manufacturer's data tag (2.7.9.2)
|
|
A17.1-2016 : Elevators
|
2.7 - Fire Extinguisher
|
8.11.2.1.2(j)
|
|
|
Machine room fire extinguisher inspection tag is from 2019, it is to be inspected and tagged annually.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.2 - Car top light and outlet
|
8.11.2.1.3(b)
|
|
|
replace car top light bulb, it was burnt out
|
|
A17.1-2016 : Elevators
|
4.5 - Access to Hoistway
|
8.11.2.1.4(e)
|
|
|
bottom landing hoistway access keyswitch is not working
|
|
A17.1-2016 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
8.11.2.1.5(a)
|
|
|
replace pit light bulb, it is burnt out
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
provide complete MCP in the machine room addording to code
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.6.11.1 Firefighters Emergency Operation: Monthly Testing
|
|
|
post monthly fire service test log in the machine room
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.5 - Car lighting and receptacles
|
8.6.4.15 Emergency Lighting
|
x
|
|
Emergency light battery is dead and needs to be replaced
|
8/30/2024
|