Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | x | Auxiliary battery lowering (emergency rescue unit) does not work, needs repaired. Re-inspection required | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Phone not working, no power. | 1/25/2023 | |
A17.1-2016 : Elevators | 5.15 - Overspeed Valve | 8.6.5.16.5 | Unsealed | 11/22/2021 |