ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.7 - Combplate and comb step impact device
|
8.6.8.4 Combplates
|
x
|
|
A center combplate on upper end has a broken tooth, replace same
|
9/13/2023
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Down combplate impact center and left settings exceed maximum allowable by code, adjust, repair & re-test. Re-inspection required
|
9/13/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.12 - Steps, step chains, and trusses
|
8.11.4.2.12
|
|
|
Entire truss needs to be cleaned out.
|
9/3/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.5 - Lighting
|
6.1.6.7
|
|
|
Lower demarcation lights don't work.
|
11/4/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.5 - Lighting
|
8.6.11.5(i) Demarcation Lighting (Re-Inspect)
|
x
|
|
Lower landing demarcation lights do not work, need repaired. Re-inspection required
|
2/24/2025
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Need to perform missing step testing. Re-inspection required
|
9/13/2023
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Need to perform required brake torque testing. Re-inspection required
|
9/13/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.17 - Step/skirt clearances, panels, and performance index
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Perform step indexing test. Re-inspection required
|
2/24/2025
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Provide brake torque test.
|
12/1/2023
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Provide missing step test.
|
12/1/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.9 - Steps and upthrust device
|
8.11.4.2.9
|
x
|
|
Replace broken step treads.
|
10/1/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.9 - Steps and upthrust device
|
8.6.8.6
|
x
|
|
There are three treads that have broken teeth. Reinspect within 90 days.
|
12/18/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.6 - Caution Signs
|
6.1.6.9
|
|
|
There needs to be caution signs posted on top and bottom landings of the escalator.
|
11/4/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.10 - Operating and safety devices
|
6.1.6.3.1 Emergency Stop Buttons (Re-Inspection)
|
x
|
|
Transparent cover missing from lower landing emergency stop switch. Install transparent cover. Re-inspection required
|
2/24/2025
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
8.6.8.14
|
|
|
Upper and lower machine spaces are dirty and need cleaned.
|
11/4/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.7 - Combplate and comb step impact device
|
8.6.8.4 Combplates
|
x
|
|
Upper end has comb plate, broken tooth.
|
12/1/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.10 - Operating and safety devices
|
6.1.6.3.1 Emergency Stop Buttons (Re-Inspection)
|
x
|
|
Upper level emergency stop switch cover does not have a buzzer when opened.
|
12/18/2019
|