Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Car lighting not working properly.
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)6 Need to post "C-1 Loading No Passengers" sign inside elevator.
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)6 Need to post "C-1 Loading No Passengers" sign inside elevator. Lettering to be at least 1/2 inch high.
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)6 Post "C-1 LOADING NO PASSENGERS" sign inside elevator.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Front and rear car gate reversing edges do not reopen the gates. 9/13/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Front and rear car gate reversing edges do not reopen gates. 9/23/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Remove spilled oil from top of car canopy
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Post emergency evacuation of passengers form inside machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x Emergency light and bell do not operate. 1/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Front and rear car gate reversing edges do not reopen gates. Car gate components need to be maintained for proper operation. 1/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No MCP
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No maintenance records on site
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Front and rear car gate reversal devices do not reopen the gate. 9/12/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No maintenance control plan in the machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No maintenance record log in the machine room
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure x Emergency light and bell do not operate. 9/2/2020
MO Minimum : Elevators (I) - Pits (I)1 Remove debris from pit.
MO Minimum : Elevators (I) - Pits (I)1 Debris in pit, remove.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light not working.
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Post firefighter operating instructions next to hall fire keyswitch
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Test and log firefighter operation monthly.
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Test and log firefighter operation monthly
MO Minimum : Elevators (S) - Fire Service (S)1 x x Elevator will not operate on fire service phase 2 operation. 1/30/2020
MO Minimum : Elevators (S) - Fire Service (S)1 x Elevator will not operate on fire service phase 2 operation. 10/24/2019
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state operating certificate inside the machine room.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current operating certificate inside machine room
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate not displayed
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State certificate not displayed in machine room