Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 Machine room access door needs to be self-locking. 9/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Post emergency evacuation of passengers form inside machine room. 9/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters Emergency Operation: Monthly Testing Test fire service operation monthly and provide documentation. 9/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 2.14.1.7 Railing and Equipment on Top of Cars Install top of car handrail. Clearance from edge of the cartop to hoistway wall exceeds 12 inches 10/18/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 2.14.1.7 Railing and Equipment on Top of Cars Top of car handrail does not have 4 inch toe board and top rail is only 36 inches in height. Overhead allows for handrail that is 42 inches in height.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.31 - Relief Valves 3.19.4.2 (Pump Relief Valve) RELIEF VALVE IS SET TOO HIGH. IT IS SET AT 570PSI AND SHOULD NOT EXCEDE 537PSI AS PER TAG ON UNIT