Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 2.14.1.7 Railing and Equipment on Top of Cars Install top of car handrail. Clearance from edge of the cartop to hoistway wall exceeds 12 inches 10/18/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 Machine room access door needs to be self-locking. 9/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Post emergency evacuation of passengers form inside machine room. 9/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.31 - Relief Valves 3.19.4.2 (Pump Relief Valve) RELIEF VALVE IS SET TOO HIGH. IT IS SET AT 570PSI AND SHOULD NOT EXCEDE 537PSI AS PER TAG ON UNIT
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters Emergency Operation: Monthly Testing Test fire service operation monthly and provide documentation. 9/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 2.14.1.7 Railing and Equipment on Top of Cars Top of car handrail does not have 4 inch toe board and top rail is only 36 inches in height. Overhead allows for handrail that is 42 inches in height.