Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A18.1-2005 : Lifts & Chairlifts 2.6 - Platforms 2.6.2 No Yes Need to attach platform floor to frame in a secure manner. 11/8/2018
ASME A18.1-2005 : Lifts & Chairlifts 2.7 - Capacity, Speed, and Travel 2.7.2 No No Need to post capacity plate 10/11/2019
ASME A18.1-2005 : Lifts & Chairlifts 2.7 - Capacity, Speed, and Travel 2.7.4 No No Need to post restriction sign inside and outside the platform. "NO FREIGHT" 10/11/2019
ASME A18.1-2005 : Lifts & Chairlifts 2.1 - Runways 2.1.1.3 No No Bottom landing hoistway door needs to be self-closing. 10/12/2023
ASME A18.1-2005 : Lifts & Chairlifts 2.1 - Runways 2.1.1.1 No No Repair hole in shaft wall. Penetrations of hoistway wall not permitted. 10/12/2023
ASME A18.1-2005 : Lifts & Chairlifts CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No Current state operating certificate not displayed in vicinity of the platform lift. 10/12/2023
ASME A18.1-2005 : Lifts & Chairlifts CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No State operating certificate not displayed 9/26/2023
ASME A18.1-2005 : Lifts & Chairlifts 2.10 - Operating Devices and Control Equipment 2.10.6 Emergency Stop Switch Yes Yes Emergency stop switch on the handicapped vertical platform lift is missing. Lift is red tagged for this safety issue 9/23/2022