ASME A18.1-2005 : Lifts & Chairlifts
|
2.1 - Runways
|
2.1.1.1
|
|
|
Repair hole in shaft wall. Penetrations of hoistway wall not permitted.
|
10/12/2023
|
ASME A18.1-2005 : Lifts & Chairlifts
|
2.1 - Runways
|
2.1.1.3
|
|
|
Bottom landing hoistway door needs to be self-closing.
|
10/12/2023
|
ASME A18.1-2005 : Lifts & Chairlifts
|
2.10 - Operating Devices and Control Equipment
|
2.10.6 Emergency Stop Switch
|
x
|
x
|
Emergency stop switch on the handicapped vertical platform lift is missing. Lift is red tagged for this safety issue
|
9/23/2022
|
ASME A18.1-2005 : Lifts & Chairlifts
|
2.6 - Platforms
|
2.6.2
|
|
x
|
Need to attach platform floor to frame in a secure manner.
|
11/8/2018
|
ASME A18.1-2005 : Lifts & Chairlifts
|
2.7 - Capacity, Speed, and Travel
|
2.7.2
|
|
|
Need to post capacity plate
|
10/11/2019
|
ASME A18.1-2005 : Lifts & Chairlifts
|
2.7 - Capacity, Speed, and Travel
|
2.7.4
|
|
|
Need to post restriction sign inside and outside the platform. "NO FREIGHT"
|
10/11/2019
|
ASME A18.1-2005 : Lifts & Chairlifts
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
Current state operating certificate not displayed in vicinity of the platform lift.
|
10/12/2023
|
ASME A18.1-2005 : Lifts & Chairlifts
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
State operating certificate not displayed
|