Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No Need a maintenance control program on site and posted on controller 11/23/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current state certificate in machine room 11/23/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.5 - Traveling cables 8.11.3.1.5(f) No No Traveling cables are cracked, needs to be replaced. Re-inspection required 1/17/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone is not working. Re-inspection required 1/11/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5.1 Examination and Maintenance of Packing Glands and Seals Yes No The packing on both jacks are leaking, need to be replaced. Re-inspection required 7/19/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.14 - Ventilation 2.14.2.3 Yes No Elevator cab ventilation fan does not work on auxiliary power (battery backup), needs repaired. Re-inspection required 10/4/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No The ADA telephone inside the elevator is not working properly. Check and repair the programming of this phone for proper operation and passenger safety. 9/2/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.18 - Restricted opening of car or hoistway doors 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) Yes No Repair inoperative door restrictor. 7 day reinspection required. Unit will be red-tagged in not repaired. 8/16/2019
conversion conversion n/a No No Packing on both jacks leaking, pit needs to be cleaned 11/23/2020
conversion conversion n/a No No Car sill is approx .1 inch above car floor, tripping hazard 11/23/2020
conversion conversion n/a No No Door restrictor must be operational 11/23/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance Yes No Cylinder head on hydraulic jack has leaking packing seal, need to replace seal. Re-inspection required 7/16/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Elevator cab emergency lights do not work, need repaired. Re-inspection required 7/16/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Elevator cab phone does not work, needs repair. Re-inspection required 12/8/2022