Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Phone in elevator cab does not work, needs repair. Re-inspection required 11/4/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.14 - Ventilation 2.14.2.3 x Elevator cab ventilation fan does not work on auxiliary power (battery backup) needs repaired. Re-inspection required 10/4/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.11 - Plunger and Cylinder 3.18 x The synchronization cables on both telescoping hydraulic jack plungers are showing signs of broken wires and deterioration. Replace synchronization cables, also replace missing synchroninization cable guard. Re-inspection required 10/4/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room 11/23/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 Need a maintenance control program on site posted on controller 11/23/2020
conversion conversion n/a Door restrictor must be operational 11/23/2020
conversion conversion n/a Packing on bith jacks leaking pit needs to be cleaned 11/23/2020