ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone in car is not working, needs repair. Re-inspection required
|
12/2/2022
|
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
2.27.2
|
x
|
|
Elevator is not transferring to generator power when the generator transfer switch is activated. Repair and reinspect.
|
2/25/2026
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
Smoke guard barrier on floor 3 is rolled up and on top of enclosure. Barrier shall be repaired so that it will work in case of emergency.
|
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
Smoke guard barrier on floor 3 is rolled up and on top of enclosure. Barrier shall be repaired so that it will work in case of emergency.
|
2/25/2026
|