A17.1-1996 : Elevators
|
3.23 - Suspension rope
|
1001.2(c)(29)
|
x
|
|
Replace all the suspension ropes as they are too short. there is not sufficent tail length beyond the shackel for proper finishing. and far to much distance between the buffer and the car counterweight. Over 3 feet.
|
9/28/2023
|
A17.1-1996 : Elevators
|
3.2 - Car top light and outlet
|
204.7
|
|
|
Provide a guard on the car top light.
|
|
A17.1-1996 : Elevators
|
3.28 - Counterweight and counterweight buffer
|
202
|
|
|
Replace the bad guide wheels on the counterweight right side.
|
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Repair the emergency phone as the incoming line is dead
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Obtain and display a current state operating certificate in the machine room
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Obtain and display a current state operating certificate in the machine room.
|
|