Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a The elevator machine room door shall be self-closing and self-locking and shall be operable from the interior space without the use of a key. 7/24/2018
MO Minimum : Elevators (H) - Machine Rooms (H)1 The elevator machine room door shall be self-closing and self-locking and shall be operable from the interior space without the use of a key. 3/26/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Floor numbers required on hoistway doors not less than 4" in height 11/21/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door shall be self locking and self closing and operable from the interior space without the use of a key. Repair the door handle to be self closing/ self locking, 11/21/2023
MO Minimum : Elevators (H) - Machine Rooms (H)1 A permanent, safe, and convenient means of access to the machine room is required. The current access door does not meet the criteria addressed in the latest code. Construct or modify access to the machine room to be safe and convenient for maintenance personnel. 11/21/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 The elevator machine room door shall be self-closing/self-locking and shall be operable from the interior space without the use of a key. Repair the door handle to be self-closing/self-locking. 11/22/2023
A17.1-2016 : Elevators 2.1 - Access to machine space 8.11.2.1.2(b) A permanent, safe, and convenient means of access to the machine room is required. The current access does not meet the criteria addressed in the latest adopted code of the State of Missouri (A17.1 2016 8.11) Construct or modify access to the elevator machine room to be safe and convenient for maintenance/emergency personnel. 11/22/2023