Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) AMaintenanceControlProgramforeachunit(see 8.6.1.1.1) shall be provided by the person(s) and/or firm maintaining the equipment and shall be viewable on- site by elevator personnel at all times from time of acceptance inspection and test or from the time of equip- ment installation or alteration 8/1/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.27 - Crosshead data plate 8.11.2.1.3(k) Need crosshead data plate 8/1/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.17 - Door and gate equipment 8.11.2.1.3(w) Safety Retainers missing from bottom of Hoistway doors.The top and bottom of horizontally sliding doors shall be provided with a means of retaining the closed door panel in position if the primary guiding means fail, 8/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6 8/1/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.17 - Door and gate equipment 8.11.2.1.3(w) 2.11.11.8 Bottom safety retainers missing from hoistway doors. The top and bottom of horizontally sliding doors shall be provided with a means of retaining the closed door panel in position if the primary guiding means fail. 8/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Provide Crosshead Data Tag 8/1/2023
A17.1-2016 : Elevators 3.23 - Suspension Means 8.6.3.2 (Re-Inspection) x Hoist Ropes showing excessive rouge have stretched reducing diameter beyond maximum allowable amount. Replace hoist ropes. 9/21/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Bottom safety retainers missing from hoistway doors. The top and bottom of horizontally sliding doors shall be provided with a means of retaining the closed door panel in position if the primary guiding means fail. 1/17/2024
A17.1-2016 : Elevators 3.27 - Crosshead Data Plate and Rope Data Tags 8.11.2.1.3(k) Provide Crosshead Data Plate compliant with section 2.16.3 1/17/2024