conversion
|
conversion
|
n/a
|
|
|
springs are not to be used if car exceeds 200 feet/min elevator needs to be slowed down and governor recalubrated
|
3/30/2021
|
A17.1-1996 : Elevators
|
2.8 - Pipes, wiring, and ducts
|
1001.2(b)(8)
|
|
|
2.8 power cables feeding controller (inside controller bare wires showing-covering is breaking down-wiring needs replaced)
|
3/30/2021
|
A17.1-2016 : Elevators
|
1.5 - Car lighting and receptacles
|
8.11.3.1.1(e)
|
|
|
Must Make Car emergency light operable.
|
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Must make Emergency Phone Operable. 8.6.4.15 (Currently calling an inactive no. )
|
10/1/2024
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1002.2f
|
x
|
|
Must make Door open and Door close buttons operable. for proper Fire service phase II operation. 211.7
|
10/1/2024
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
211.3a(8) Visual and audible signal
|
x
|
|
Must make both Audible and Visual Signals operable on Fire service activation. 211.3a(8)
|
10/1/2024
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Must make Emegency phone operable. 8.6.4.15
|
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1002.2f
|
x
|
|
Must Make Door Open and Door Close Buttons Operable. For proper Fire Service Phase II operation 211.7
|
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
211.3a(8) Visual and audible signal
|
x
|
|
Must make Both Audible and Visual signals operable upon activation of fire service. 211.3a(8)
|
|
A17.1-1996 : Elevators
|
5.9 - Buffers and emergency terminal speed limiting devices
|
201
|
x
|
|
Car exceeds max. speed for spring buffers (car currently running 275 f.p.m.) 201.1
|
12/14/2020
|
A17.1-1996 : Elevators
|
5.9 - Buffers and emergency terminal speed limiting devices
|
201
|
x
|
|
201.1 spring buffers are not to be used if elevator exceeds 200 frt per min (elevator tacked at 275' per min)
|
9/6/2019
|