Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.1 No No Removce all stored material and equipment from the access pathway to the elevator machine room, You must maintain a minimum of 36" clear. 8/15/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.1 No No Provide a clear, 36", means of egress to the machine room at all times. 7/2/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Obtain and display a current state operating certificate in the machine room. 7/2/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.2.2 No No Remove all the stored equipment from in front of the elevator machine room door. You must maintain a clear pathway to the equipment. 9/12/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1.1.1 Means of Communication (Red Tag) No No Re program the emergency phone to someone who can take appropriate action in case of emergency. 7/1/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.5 - Housekeeping 8.6.4.8 Machine Rooms and Machinery Spaces No No Replace the drywall in the machine room back to the original 1 hour rated assembly. 9/12/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits No No Clean up the pit and remove all the black mold from the pit walls. 9/12/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Repair the emergency as you cannot understand anything the person on the other end is saying as there is so much static on the line. 7/13/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 No No REpair or replace the machine room door as it will not self close or self lock. 4/26/2024
conversion conversion n/a No No Provide a complete set of keys to all phases of the elevator operation. 8/15/2019
conversion conversion n/a No No Repair the emergency phone as there is no dial tone 8/15/2019
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Obtain and display a curent state operating certificate in the machine room 9/7/2022