ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - n/a
|
n/a
|
|
|
Water in pit needs to be removed
|
12/26/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.6 - Governor-rope tension devices
|
8.11.2.1.5(g)
|
|
|
Governor tension sheave shall be replaced. 1" rod holding sheave is rusted out.
|
12/26/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.9 - Buffers and emergency terminal speed limiting devices
|
8.11.2.1.5(c)
|
|
|
Check integrity of pit buffers.
|
12/26/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.1 - Access to machine space
|
2.7.3.4
|
|
|
Machine room door shall be self closing and locking, and steps leading up to room shall be attached.
|
12/26/2019
|
conversion
|
conversion
|
n/a
|
|
|
Remove standing water from the elevator pit
|
12/31/2018
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Repair inoperative emergency phone
|
8/9/2018
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Pit shall be kept clean of dirt and water.
|
12/31/2018
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Tail sheave needs to be replaced due to water damage.
|
12/31/2018
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door shall be self closing and self locking.
|
12/31/2018
|
MO Minimum : Elevators
|
(N) - Guide Rails
|
(N)2
|
|
|
Check integrity of all rail bottoms (under water and large amounts of rust flaking off). 5.13
|
12/26/2019
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)1
|
|
|
Steps leading up to room shall be attached.
|
12/25/2020
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door shall be self-closing and self-locking.
|
12/25/2020
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room access door needs repair, door hinges pulled from frame and door.
|
12/25/2020
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Test incomplete - Governor must be tested for electrical and jaw speeds. Re-inspection required
|
12/2/2022
|