Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current state operating certificate shall be displayed inside of the elevator machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No A valid fire extinguisher shall be kept inside of the elevator machine room.
MO Minimum : Elevators (N) - Guide Rails (N)2 No No Check integrity of all rail bottoms (under water and large amounts of rust flaking off). 5.13 12/26/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.9 - Buffers and emergency terminal speed limiting devices 8.11.2.1.5(c) No No Check integrity of pit buffers. 12/26/2019
MO Minimum : Elevators (I) - Pits (I)1 No No Elevator pit shall be kept dry and clean from all water or debris. Remove all water from elevator pit.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.6 - Governor-rope tension devices 8.11.2.1.5(g) No No Governor tension sheave shall be replaced. 1" rod holding sheave is rusted out. 12/26/2019
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room access door needs repair, door hinges pulled from frame and door. 12/25/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.4 No No Machine room door shall be self closing and locking, and steps leading up to room shall be attached. 12/26/2019
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self closing and self locking. 12/31/2018
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self-closing and self-locking. 12/25/2020
MO Minimum : Elevators (I) - Pits (I)1 No No Pit shall be kept clean of dirt and water. 12/31/2018
conversion conversion n/a No No Remove standing water from the elevator pit 12/31/2018
conversion conversion conversion - reinspect Yes No Repair inoperative emergency phone 8/9/2018
MO Minimum : Elevators (H) - Machine Rooms (H)1 No No Steps leading up to room shall be attached. 12/25/2020
MO Minimum : Elevators (I) - Pits (I)1 No No Tail sheave needs to be replaced due to water damage. 12/31/2018
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Test incomplete - Governor must be tested for electrical and jaw speeds. Re-inspection required 12/2/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - n/a n/a No No Water in pit needs to be removed 12/26/2019