Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.10 - Operating and safety devices 6.1.6.3.1 Emergency Stop Buttons (Re-Inspection) x Escalators shall have a clear plastic cover over emergency stop switches with an audible alarm which is activated by lifting the cover. Re-inspection required 12/7/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) x Replace broken demarcation strips. 9/23/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.3 Step/Skirt Performance Index x Step indexing was not done. Must complete step indexing, must also perform the brake torque test 12/1/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.5 Escalator Skirt Panels Test not complete - no indexing 10/11/2019
A17.1-1996 : Escalators 7.10 - Operating and safety devices 805.3a Escalator shall have a clear plastic cover over emergency stop switches with an audible alarm which is activated by lifting the cover
conversion conversion n/a The audio signal that activates when the stop switch cover is lifted is not operational and shall be repaired. This audio signal also activates when the escalator handrail has stopped. 10/11/2019