Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Escalators 7.10 - Operating and safety devices 805.3a Escalator shall have a clear plastic cover over emergency stop switches with an audible alarm which is activated by lifting the cover
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.10 - Operating and safety devices 6.1.6.3.1 Emergency Stop Buttons (Re-Inspection) x Escalators shall have a clear plastic cover over emergency stop switches with an audible alarm which is activated by lifting the cover. Re-inspection required 12/7/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.5 Escalator Skirt Panels Test not complete - no indexing 10/11/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 8.6.8.6 x Replace three broken step treads. 9/23/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.2 - Stop switch 8.11.4.2.2 x Replace cover on upper landing stop switch. 9/23/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 6.1.3.4 (Hand rails) (Re-Inspection) Handrails cracking. Shall be replaced 3/9/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.3 Step/Skirt Performance Index x Step indexing incomplete. Shall finish step indexing test and brake torque test 12/1/2021
conversion conversion n/a A comb plate has a broken tooth and shall be replaced. 10/11/2019