MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Pits need to be kept dry. Sump pump ntot working. Pit has 2 inches of standing water.
|
7/31/2018
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.11.1 Firefighters' Emergency Operation & Documentation
|
|
|
Teat and log firefighter operation monthly
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.5.5.2 Oil Leakage Collection
|
|
|
Cylinder drain line runs back to storage tank. Remove from tank and install into pit collection container
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
EMERGENCY PHONE NOT WORKING
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
|
Emergency light does not operate.
|
1/19/2021
|